Wednesday, July 3, 2013

Testing stuff!!!!!!!!!

Whew! 2 solid days of testing. Monday was spent testing different places we could place the CO2 sensor.
First, I tested with the CO2 sensor on the bottom of the enclosure.
I had expected the CO2 to settle on the bottom and give a much larger reading than the true reading. I knew how much CO2 I was putting in because I was measuring it with a large syringe. I would put the mouth of the syringe in the bottom of a bucket that had dry ice in it for quite awhile. I would slowly draw the gaseous CO2 into the  syringe, and then set the syringe in a vertical orientation so that when it came to room temp, it would push the excess CO2 out of the top end of the syringe. I made some calculations to arrive at 5mL of room temp CO2 was adding 80.3ppm by mass (79.7 by volume) to the container we were using. Anyway, back to my hypothesis. I figured that if I added CO2 to the enclosure (to bring it up to 1000ppm), it would pool in the bottom where the sensor was and give a reading far above 1000ppm. I was half right. If I can put a copy of the graph in this I will. The reading from the grey wolf spiked high every time I put CO2 in (50mL per injection), but after about 6 minutes, it would achieve a steady state.
The steady state value almost agreed with the ppm I thought I was putting in (700ppm compared to the 800ppm I believed i was putting in), but I had not anticipated this. My interpretation of the spike goes along with my initial hypothesis. The CO2 is just really heavy compared to air. However, I thought it would stay at that high level. I was really surprised that the CO2 diffused throughout the enclosure.

Next came the middle test where the sensor was located vertically in the middle of he chamber.

I kept the 50mL addition the same every time, but the initial spike from the low test was smaller, and the time to reach equilibrium was much longer, about 15 minutes.

Even though I was adding 800ppm every time (from calculations based on the syringe), the steady state averaged out to about a 500ppm increase each time....hmmm.

High test

The grey wolf was put at the top of the container as well as our sensor, to do some initial voltage measurements.
I was concerned about this last graph, because I thought something had gone wrong. I couldn't find anything wrong with the set-up, so it must be accurate. As Julius Sumner Miller stated "Experiments do not fail, you must provide Nature the necessary provisions, or she won't do what you want her to do."
We added 160ppm at 3:51 and got a reading of about a 21ppm increase 3 minutes later.
We added 320ppm at 3:54 and got a reading of about a 400ppm increase 8 minutes later.
We added 320ppm at 4:03 and got a reading of about a 260ppm increase 7 minutes later.
We added 480ppm at 4:10 and got a reading of about a 410ppm increase 6 minutes later.
We added 800ppm at 4:16 and got a reading of about a 630ppm increase 11 minutes later.

The ideas of what was going on was starting to coalesce in my head. I had imagined the CO2 like it was water, sinking to the bottom of the container and staying there. That was the model in my head of the system. To paraphrase Kenn Amdahl, when pretending the universe is like a watermelon, with the seeds like stars, don't forget that the universe isn't actually a watermelon. What I had failed to account for was that CO2 is a compressible fluid and water is not. This new-found realization crystallized and it made sense of the data. What actually was occurring when CO2 was added, was an initial plunge as the CO2 dropped to the bottom of the container. As the gas diffused, it also set up a density gradient, with the highest density at the bottom, and decreasing as you go vertically upward. That at least partially explains the discrepancy between the ppm injected and the ppm measured. I need to do a little research a little into this phenomenon. The fluid mechanics class I took was a long time ago, and I'm not sure if we covered compressible fluids.
Dave out



Monday, July 1, 2013

Ready to test!

Ok, I think we're at a stage where we can begin testing.

  • First, measuring CO2 at different heights of the big tub. Hoping it will answer a question I have about how fast the CO2 will sink since it is much denser than air. Measure the concentration low, middle, high with the grey wolf given a known ppm.  
  • I have calculated the ppm CO2 (by weight and by volume (for those of you playing at home, its only .16% different)) we will be adding to each of our containers per mL of CO2 we add from a large syringe.
  • I measured and calculated the actual volume of our enclosures +/- 2% for the bucket, and +/- 5% on the enclosure.  These measurements were about 10% off from the listed size of the bucket, and less than 1% off for the enclosure.
  • I should be able to show my team and whoever else the bubbles floating on the CO2 that we were going to employ at Tech Fest. I'll insert a video later today 
Parsons

Vaisala CO2 info

I have looked & looked for a company that deals with CO2 sensing combined with ventilation.  I found lots of good information on several types of sensing units from a company called Vaisala.  I have sent an email requesting more information about the company & where the sensor are manufactured.  I could only locate sales offices from the web page, but was able to get spec sheets for the sensors.  This company advertizes that they have applications appropriate for home, school, and business.  I will see what else I can determine about the company that is not on the web page.

Friday, June 28, 2013

Shopping Trip!!!!!

Dave, Dawn, & myself went to Lowes for testing supplies.  We wanted to add materials to our "plastic test room" that would simulate the types used in walls, floors, and ceilings actually present in schools.  We purchased carpet & tile flooring samples, 2 plants, a concrete cinder block, and a bucket with a lid that can be sealed.  We will add CO2 to the bucket & use our battery powered sensor to check for different results. (OH....we also bought two 9V batteries.)  Dave and Sharin are currently brain storming on the battery power issue.  Hopefully by mid day on Monday we will be able to go get dry ice (CO2 source) & begin testing. 

Happy Friday!

Presentation & more

I think that the Prezi that Dave put together was AWESOME!  It was informational & everyone in the room seemed to enjoy it.  It might not be appropriate for a Scientific Panel to review, but it would definately keep our students interested in the material being presented.  Seems like Prezi might be better for keeping students engaged than Power Point is!  Will have to test this theory when school starts.

Suprise Surprise.....The amplifier/filter part we needed to make the CO2 sensor function properly arrived this morning!  We can now concentrate on CO2 levels triggering a fan instead of only using VOC.  We will continue to use VOC measurements in our documentation, but our primary focus will now be on CO2 levels.

Wednesday, June 26, 2013

Today's activities

Dave, Dawn, Sahrin, and myself met with Dr. Rudi Thompson this morning regarding project progress & proposed tech fest activities.  I am very proud to say that Dr. Rudi liked our proposed activity for tech fest enough that she wants to add it as a permanent activity for children who visit EESAT.  Kuddos Dave for thinking of such a fun CO2 activity.

We also have more direction on proposed testing for our VOC monitoring.  We will gather supplies for our mini-building and test our ideas regarding the effects of different materials on VOCs.  Current suggestions include concrete cinder blocks (un painted & painted), sheet rock (un painted & painted), carpet, ceiling tiles, brick, tile flooring, laminate flooring, and wood (either flooring or paneling for walls).  We will also test using plants to check for variations.  It will be interesting to see the results.

We are also going to use a smaller container (maybe a Homer Bucket) with a lid that seals better than the container we currently use for a test room.  We will have to work out the issue of having the wires to the sensor (don't have battery operation worked out yet) not getting pinched or keeping the container from being as air tight as possible.

Dave is also working on a Prezi that is "out of sight" for our Friday Presentation meeting. 
Very Interesting and Entertaining for all!

Tuesday, June 25, 2013

We tested the programming for the sensor today to make sure it would turn on and back off the ventillation fan as wanted.  The pictures below were taken during setup and testing.  It appears the ventillation fan doesn't move air very quickly, or we need to use a smaller container to represent the room.  Dave had to take the lid off of the container & fan fresh air into it to get the sensor to shut off the fan.  Something else to think about!

Sharin & Dave setting up test.

Sensor in container to simulate room.

Ventillation fan.

Complete sensor set up with fan running during test.